Oil test aerosol of polyalphaolefin, commonly used for in-situ leak testing of installed HEPA filters.
It is typically generated with a Laskin nozzle and measured with an aerosol photometer or particle counter during cleanroom filter integrity tests.
- Standards
- ISO 14644-3
The force per unit width needed to separate the layers of a laminate, used as a measure of bond quality.
Measured on a tensile tester by peeling one layer from another at a set speed. It is checked before and after washing to predict delamination risk.
- Unit
- N/cm
- Standards
- ASTM D2724
The fraction of particles upstream of a filter that pass through it, equal to one minus the filtration efficiency.
Penetration is convenient for high-efficiency filters: 99.95% efficiency equals 0.05% penetration. It is the quantity used in the quality factor and in EN 1822 and ISO 29463 classification.
- Unit
- %
- Standards
- EN 1822, ISO 29463
Flux through a membrane divided by the transmembrane pressure, expressing how easily liquid passes per unit driving force.
Membrane permeability is commonly quoted in LMH/bar. A falling permeability at constant conditions is the usual indicator of fouling.
- Unit
- L/(m²·h·bar)
Stream that has passed through a membrane, also called filtrate.
In water treatment the permeate is usually the product; in protein or juice concentration the retained stream may be the product instead.
Per- and polyfluoroalkyl substances, a large class of fluorinated chemicals, used in textiles for water and oil repellency and in fluoropolymer membranes.
Several jurisdictions have adopted or proposed restrictions on PFAS in apparel because of persistence. Definitions differ between regulations, which matters for whether fluoropolymers such as PTFE are covered.
A water-repellent finish containing no fluorinated chemistry, based for example on hydrocarbons, silicones, waxes or dendrimers.
C0 finishes can reach good water spray ratings but generally provide little or no oil repellency, so stain resistance and durability need separate verification.
The shape parameters of a pleated filter pack, chiefly pleat height, pleat pitch (spacing) and pleat form.
Too few pleats leave media velocity high; too many make adjacent pleats crowd and raise pressure drop. An optimum pleat count exists for each medium and dust load.
Folding filter media into a series of pleats to fit a large media area into a small filter element.
Pleating lowers media velocity and pressure drop and raises dust holding capacity. Media must be stiff enough to keep pleat shape, and fine layers such as nanofibers must survive the folding.
Calender bonding with an engraved roll that fuses the web only at a regular pattern of discrete points.
The bonded area is a minority of the surface, so the material keeps more flexibility, softness and permeability than with area bonding.
The sign of the high voltage applied to the spinneret or collector, positive or negative, which affects jet behavior, charge on fibers and discharge behavior.
Positive spinneret polarity with a grounded collector is most common. Some systems split voltage with opposite polarities on spinneret and collector to reach a high total potential difference.
A polymer widely electrospun from DMF solution and the main precursor for carbon nanofibers.
PAN nanofibers are used directly in filtration and, after oxidative stabilization in air and carbonization in inert gas, become carbon nanofibers.
An aliphatic polyamide with a higher melting point than PA6, electrospun where better thermal resistance is needed.
Its melting point is around 295 °C, compared with about 220 °C for PA6.
A semicrystalline aliphatic polyamide, also called nylon 6, among the most widely electrospun polymers for filtration nanofibers.
It is commonly spun from formic acid or formic and acetic acid mixtures. Its melting point is around 220 °C, and it absorbs some moisture.
A biodegradable polyester with a low melting point near 60 °C, widely electrospun for tissue engineering and drug delivery.
It degrades slowly compared with PLA and is often blended with natural polymers such as collagen or gelatin to improve cell interaction.
Polyethylene terephthalate, a thermoplastic polyester used for staple fibers and spunbond with higher temperature resistance than polypropylene.
Melting point is about 250–260 °C. Recycled PET from bottles is widely used as staple fiber and increasingly in spunbond.
A monolithic hydrophilic membrane made from thermoplastic polyether-ester elastomer, transporting vapor through its hydrophilic polyether segments.
It is fluorine-free and, when laminated to polyester textiles, supports single-polymer-family garment concepts aimed at easier recycling.
An amorphous, high-temperature thermoplastic electrospun for membranes and filtration where thermal and chemical stability are needed.
PES is a well-known membrane polymer and is typically spun from polar aprotic solvents such as DMF or DMAc.
A water-soluble polymer that spins easily and is often used as a carrier to help electrospin polymers that do not spin well alone.
High-molecular-weight PEO supplies chain entanglement for biopolymers such as chitosan. It can be washed out after spinning if water resistance is needed.
A bio-based, biodegradable polyester electrospun for biomedical scaffolds, packaging and compostable filter media.
Degradation rate and properties depend on stereochemistry and crystallinity. Chlorinated or fluorinated solvents are often used, which makes solvent residue relevant.
The fraction of polymer in the spinning solution, a primary control of viscosity, chain entanglement and resulting fiber diameter.
Below a critical concentration, jets break into droplets or beaded fibers; higher concentrations generally increase fiber diameter until the solution becomes too viscous to spin.
- Unit
- wt%
A semicrystalline, heat- and chemical-resistant polymer used in hot-gas filtration, difficult to solution-electrospin due to limited solubility.
PPS does not dissolve in common solvents at room temperature, so PPS fine fibers are usually made by melt-based or other non-standard routes.
A low-density thermoplastic polyolefin and the most widely used polymer for spunbond and meltblown nonwovens.
Density is about 0.90–0.91 g/cm³ and the melting point around 160–165 °C. It is hydrophobic, chemically resistant and holds electret charge well.
- Also used in
- Nanofiber materials
An amorphous, tough thermoplastic closely related to PES, electrospun for membranes and filtration media.
Like PES, it is soluble in polar aprotic solvents and is widely used in conventional membrane manufacturing.
An elastomeric polymer family electrospun into stretchable, soft nanofiber webs for membranes, textiles and biomedical uses.
Properties vary widely with chemistry, so the specific grade matters. Common solvents include DMF and THF, alone or mixed.
A waterproof breathable film made from thermoplastic polyurethane, produced in monolithic hydrophilic or microporous form.
PU membranes are fluorine-free, comparatively low cost and can be highly elastic, which suits stretch laminates. Hydrolysis resistance of the chosen PU grade affects long-term durability.
A water-soluble polymer readily electrospun from aqueous solution, usually crosslinked when water resistance is required.
Water-based spinning avoids organic solvents. PVA is also used as a carrier polymer for biopolymers and inorganic precursors.
A hydrophobic, chemically resistant fluoropolymer electrospun for membranes, battery separators and piezoelectric applications.
Electrospinning can promote its polar beta phase, which is responsible for piezoelectric behavior. Common solvents include DMF or DMAc, often mixed with acetone.
A polymer soluble in water and ethanol, commonly used as a carrier for ceramic precursor nanofibers and in fast-dissolving fiber formulations.
In ceramic nanofiber production, PVP holds the sol-gel precursor in fiber form and is burned off during calcination.
Characteristic diameter of the openings in a porous filter or membrane, defined by the measurement method used to determine it.
Different methods (bubble point, capillary flow porometry, microscopy, particle challenge) give different values for the same medium, so a pore size should always be quoted with its method.
- Unit
- µm
- Also used in
- Nanofiber materials
Statistical spread of pore diameters in a porous medium, usually reported as the fraction of flow or of pores within each size interval.
A narrow distribution gives a sharper separation cutoff. Electrospun nanofiber media are often characterized by capillary flow porometry, which reports largest, mean flow and smallest pore sizes.
- Unit
- µm
- Standards
- ASTM F316
The fraction of the total volume of a material that is void space.
Porosity says nothing about pore size; two webs with equal porosity can have very different pore sizes and permeability depending on fiber diameter.
- Unit
- %
- Also used in
- Nanofiber materials
Fibers with pores on their surface or within their body, which increase specific surface area beyond that of solid fibers.
Pores can form through phase separation, for example with volatile solvents or high humidity, or by selectively removing one component of a blend.
Lamination in which thermoplastic adhesive powder is scattered onto a substrate, melted and then pressed against the second layer.
It creates a random, open adhesive distribution and needs no solvent. Control of particle size and scatter weight determines bond uniformity.
Coarser filter placed upstream of a finer filter or membrane to remove larger particles and extend the downstream filter's service life.
Correct prefilter selection balances cost against the life of the final filter. Depth cartridges, bag filters and media filters are typical prefilters.
The difference in static pressure between the upstream and downstream sides of a filter medium or filter at a stated airflow.
Also called airflow resistance. In clean fibrous media it rises roughly linearly with velocity, and it determines the fan energy a filter costs over its life.
- Unit
- Pa
- Standards
- ISO 16890, EN 1822, ASHRAE 52.2
Integrity test that pressurizes the upstream side of a wetted filter and measures pressure decay over a fixed time.
Also called pressure decay test. It is derived from diffusion flow and depends on upstream volume and temperature stability, so acceptance limits are specific to the filter and setup.
- Unit
- mbar
The air and solution temperature in the spinning zone, which influences viscosity, surface tension and solvent evaporation rate.
Temperature and humidity should be controlled and recorded together, since relative humidity changes with temperature.
- Unit
- °C
The range of process, solution and ambient parameter combinations within which a product can be spun stably and within specification.
A wide window makes production robust against normal variation. Mapping it systematically, for example with DOE, is a core part of process development.
A European standard specifying requirements and performance classes for garments protecting against rain, fog and ground humidity.
Classes are based mainly on water penetration resistance and water vapor resistance of materials and seams, which makes it a common reference in workwear tenders.
- Standards
- EN 343
Cleaning method in which short reverse pulses of compressed air remove the dust cake from the surface of cleanable filter media in operation.
Used in dust collectors and gas turbine inlets. Media with surface filtration, such as nanofiber-coated or membrane media, release dust better and keep residual pressure drop lower.
- Standards
- ISO 11057, VDI 3926